beautypg.com

5 dynamic brake (db) units – Yaskawa Sigma II Series SGMVH User Manual

Page 34

background image

2 Selections

2.5.5 Dynamic Brake (DB) Units

2-10

2.5.5 Dynamic Brake (DB) Units

Externally attach a dynamic brake resistor to the SERVOPACK to dissipate regenerative energy when using the
dynamic brake function. The dynamic brake resistor does not need to be installed if the dynamic brake function is
not required.

Use the dynamic brake unit under the following conditions. Contact your Yaskawa representative before using
the unit under conditions more severe than those specified below.

• Allowable load moment of inertia: 5 times the load moment of inertia
• Allowable duty: Less than one DB stop per hour at maximum rotation speed

Dynamic Brake

(DB) Unit Model

SERVOPACK Model

Resistance

Specifications

(Star Wiring

)

DB Contactor and

Surge Absorption Unit

SGDM-

SGDH-

JUSP–DB01

2BADB, 3ZADB

2BAEB, 3ZAEB

180 W, 0.3

Ω

Built into the
SERVOPACK

JUSP–DB02

3GADB

3GAEB

180 W, 0.3

Ω

Built into Dynamic Brake
Unit

JUSP–DB03

2BDEB, 3ZDEB

180 W, 0.8

Ω

Built into the
SERVOPACK

JUSP–DB04

3GDEB

180 W, 0.8

Ω

Built into Dynamic Brake
Unit

JUSP–DB05

4EDEB

180 W, 0.8

Ω

Built into Dynamic Brake
Unit

JUSP–DB06

5EDEB

300 W, 0.8

Ω

Built into Dynamic Brake
Unit

JUSP–DB12

9ZDEB

600 W, 0.9

Ω

Built into Dynamic Brake
Unit