beautypg.com

37 (3) internal connection diagram, 4) connections – Yaskawa Sigma II Series SGMVH User Manual

Page 118

background image

5.5 Peripheral Devices

5

Specifications and Dimensional Drawings of Cables and Peripheral Devices

5-37

(3) Internal Connection Diagram

The following connection diagram is for a TR-3N thermal relay.

(4) Connections

Connect the thermal relay as shown in the following diagram.
When the thermal relay operates, the auxiliary contact turns OFF or ON. Therefore, configure a sequence so that
the main power supply or the servomotor turns OFF when the auxiliary contact turns OFF or ON.

(a) Connecting to a Regenerative Resistor Unit

(b) Connecting to a Dynamic Brake Unit

1

2

3

4

5

6

97

95

98

96

(NO) (NC)

(NO) (NC)

SGDM/SGDH
SERVOPACK

Thermal relay

Regenerative
Resistor Unit

Auxiliary contact

To host controller

B1

B2

B1

B2

Thermal relay

Dynamic Brake Unit

Auxiliary contact

To host controller

DV

DW

DU

DW

DU

DV

SGDM/SGDH
SERVOPACK