beautypg.com

Yaskawa Sigma II Series SGMVH User Manual

Page 328

background image

11 Appendix

11.3.2 List of Parameters

11-26

Pn50D

Input Signal Selections 4

8888

After restart

Pn50E

Output Signal Selections 1

3211

After restart

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

0

1

2

3

0 to F Same as /ZCLAMP

Same as /ZCLAMP

ON when CN1-40 input signal is ON (L-level).

ON when CN1-41 input signal is ON (L-level).

ON when CN1-42 input signal is ON (L-level).

ON when CN1-43 input signal is ON (L-level).

ON when CN1-44 input signal is ON (L-level).

ON when CN1-45 input signal is ON (L-level).

ON when CN1-40 input signal is OFF (H-level).

ON when CN1-41 input signal is OFF (H-level).

ON when CN1-42 input signal is OFF (H-level).

ON when CN1-43 input signal is OFF (H-level).

ON when CN1-44 input signal is OFF (H-level).

ON when CN1-45 input signal is OFF (H-level).

ON when CN1-46 input signal is OFF (H-level).

ON when CN1-46 input signal is ON (L-level).

/ZCLAMP Signal Mapping (Zero clamp when ON (L-level))

/INHIBIT Signal Mapping (Reference pulse inhibit when ON (L-level))

/G-SEL Signal Mapping (Gain change when ON (L-level))

Reserved (Do not change)

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

0 to F

4

5

6

7

8

9

A

B

C

D

E

F

Sets signal OFF.

Sets signal ON.

0

1

2

3

0 to 3

Disabled (the above signal is not used.)

Outputs the signal from CN1-25, 26 output terminal.

Outputs the signal from CN1-27, 28 output terminal.

Outputs the signal from CN1-29, 30 output terminal.

Same as /COIN

Same as /COIN

Same as /COIN

Positioning Completion Signal Mapping (/COIN)

Speed Coincidence Detection Signal Mapping (/V-CMP)

Rotation Detection Signal Mapping (/TGON)

Servo Ready Signal Mapping (/S-RDY)

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

0 to 3