beautypg.com

23 (b) example of changing function selection – Yaskawa Sigma II Series SGMVH User Manual

Page 172

background image

7.3 Operation in Parameter Setting Mode (Pn†††)

7

Digital Operator/Panel Operator

7-23

(b) Example of Changing Function Selection

The procedure to change the setting of control method selection (Pn000.1) of the function selection basic
switches (Pn000) from speed control to position control is shown below.

Step

Display after

Operation

Digital

Operator

Panel Operator

Description

1

Press the DSPL/SET or MODE/SET Key to select the
parameter setting mode. If a parameter other than Pn000
is displayed, press the UP or DOWN Key to select the
Pn100.

Note: The enable digit blinks.

2

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The current data of
Pn000 is displayed.

3

Press the LEFT or RIGHT or DATA/SHIFT Key to
select the first digit of current data.

4

Press the UP Key once to change to “n.0010.”
(Set the control method to position control.)

5

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The value blinks and is
saved.

6

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the display
Pn000. The control method is changed to position con-
trol.

7

To enable the change in the setting of function selection basic switches (Pn000), turn OFF the power and ON again.

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

DATA/

(DATA/SHIFT Key)

(UP Key)

(UP Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)