8.1 Trial Operation

8

Operation

8-9

8.1.2 Trial Operation for Servomotor without Load from Host Reference

Check that the servomotor move reference or I/O signals are correctly set from the host controller to the SERVO-
PACK. Also check that the wiring and polarity between the host controller and SERVOPACK, and the SERVO-
PACK operation settings are correct. This is final check before connecting the servomotor to the machine.

(1) Servo ON Command from the Host

The following circuits are required: External input signal circuit or equivalent.

Change the SEN signal (CN1-4) to the H level when an absolute encoder is used.

Speed Control

(Standard Setting)
[Pn000=n.††0†]

Position Control

[Pn000=n.††1†]