5.5.10 Regenerative Resistor Unit

(1) Model

Refer to the following table to install the regenerative resistor unit according to the SERVOPACK model require-
ments.

(2) Mounting

To cool the regenerative resistor by fan or natural convection, provide at least 70 mm of space on each side and at
least 200 mm of space both above and below.

SERVOPACK Model

Regenerative Resistor Unit

Allowable

Power Loss

W)

Model

Resistance

Ω)

Resistance

Capacity(W)

SGDM-2BADB
SGDH-2BAEB

JUSP-RA08

2.4

2400

480

SGDM-3ZADB
SGDH-3ZAEB

JUSP-RA09

1.8

4800

960

SGDM-3GADB
SGDH-3GAEB

JUSP-RA11

1.6

4800

960

SGDH-2BDEB

JUSP-RA12

9

3600

720

SGDH-3ZDEB

JUSP-RA13

6.7

3600

720

SGDH-3GDEB

JUSP-RA14

5

4800

960

SGDH-4EDEB

JUSP-RA15

4

6000

1200

SGDH-5EDEB

JUSP-RA16

3.8

7200

1440

SGDH-9ZDEB

JUSP-RA25

2.1

16800

3360

70 min.

70 min.

200 min.

200 min.

Mounting
direction

Up