8.9.2 External Torque Limit (Output Torque Limiting by Input Signals)

8-72

8.9.2 External Torque Limit (Output Torque Limiting by Input Signals)

This function allows the torque to be limited at specific times during machine operation, for example, during
press stops and hold operations for robot workpieces.
An input signal is used to enable the torque limits previously set in parameters.

(1) Related Parameters

Note: The setting unit is a percentage of rated torque (i.e., the rated torque is 100%).

(2) Input Signals

(3) Changes in Output Torque during External Torque Limiting

Example: External torque limit (Pn402, Pn403) set to 800%

Note: In this example, the servomotor rotation direction is Pn000 = n.†††0 (standard setting, CCW =

forward).

Pn404

Forward External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

1%

100

Immediately

Pn405

Reverse External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

1%

100

Immediately

Speed

Position

Torque

Speed

Position

Torque

Type

Signal

Name

Connector Pin

Number

Setting

Meaning

Limit Value

Input /P-CL

CN1-45
(Factory Setting)

ON (low level)

Forward external torque limit
ON

The value set in Pn402 or
Pn404 (whichever is smaller)

OFF (high level)

Forward external torque limit
OFF

Pn402

Input /N-CL

CN1-46
(Factory Setting)

ON (low level)

Reverse external torque limit
ON

The value set in Pn403 or
Pn405 (whichever is smaller)

OFF (high level)

Reverse external torque limit
OFF

Pn403

When using this function, make sure that there are no other signals allocated to the same terminals as /P-CL and /N-CL.
When multiple signals are allocated to the same terminal, the signals are handled with OR logic, which affects the ON/OFF
state of the other signals. Refer to 7.3.2 Input Circuit Signal Allocation

.

/P-CL (Forward External Torque Limit Input)

High level

Low level

/N-CL

(Reverse

External

Torque Limit

Input)

High
level

Low

level

Pn403

Pn402

0

Torque

Speed

Pn403

0

Pn404

Pn402

Torque

Speed

0

Pn403

Pn405

Pn402

Torque

Speed

0

Pn403

Pn405

Pn404

Pn402

Torque

Speed