beautypg.com

1 interface circuits, Sen signal connection – Yaskawa Sigma II Series SGMVH User Manual

Page 210

background image

8.4 Absolute Encoders

8

Operation

8-29

8.4.1 Interface Circuits

The following diagram shows the standard connections for a an absolute encoder mounted to a servomotor. The
connection cables and wiring pin numbers depend on the servomotor. For details, refer to chapter 5 Specifica-
tions and Dimensional Drawings of Cables and Peripheral Devices
.

* 1. :

Represents twisted-pair wires.

* 2. For wiring pin numbers, refer to 5 Specifications and Dimensional Drawings of Cables and Peripheral Devices.

• SEN Signal Connection

Applicable line receiver: Texas Instruments’s SN75175 or the equivalent
Terminating resistance R: 220 to 470

Ω

R

BAT (+)

BAT (-)

PG5 V

PG0 V

PS

/PS

BAT(-)

PCO

/PCO

PBO

/PBO

PAO

/PAO

BAT(+)

SEN

SG

R

R

PA

PB

PC

PS

+5 V

7406

0 V

+

-

4
2

21

22

33
34
35
36
19

1

20

CN1

3

4

5

6

2

1

CN2

UP

DOWN

SG

0 V

Host controller

Battery

SERVOPACK

Encoder

Serial interface
circuit

Serial interface

circuit

Line receiver

Edge
detection

Up/down
counter

Clear

Shield (shell)

Connector

shell

R

PSO

/PSO

48
49

PG

∗1

∗1

∗2

Type

Name

Connector

Pin Number

Setting

Meaning

Input

SEN

CN1-4

OFF (low level)

Input when power is turned ON

ON (high level)

Input at absolute data request

• This input signal is required to output absolute data

from the SERVOPACK.

• When the SERVOPACK main circuit power supply

turns OFF, input the SEN signal at a low level.

• Let at least three seconds elapse after turning ON the

power before changing the SEN signal to high level.

• When the SEN signal changes from low level to high

level, the multiturn data and initial incremental
pulses are output.
Until these operations have been completed, the ser-
vomotor cannot be turned ON regardless of the status
of the servo ON signal (/S-ON).

• The panel operator display will also remain “b.b”.

Refer to 8.4.6 Absolute Encoder Reception Sequence.

„ IMPORTANT

Maintain the high level for at least 1.3 seconds when the SEN
signal is turned OFF and then ON, as shown in the figure on the
right.

4.7 k

SEN

4

CN1

SG

2

+5V

0V

100

Ω

Ω

0V

0.1

μ

Host controller

SERVOPACK

High level:

About 1 mA

7406 or equivalent

We recommend a PNP transistor.
Signal levels
High: 4.0 V min. Low: 0.8 V max.

OFF

ON (high level)

1.3 s min.

OFF

ON

15 ms min.

SEN signal