beautypg.com

2 error messages, Faulty range data, Rotation not permitted – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 90: Wrong axis programmed, Scaling factor not permitted, Stylus already in contact, Probe system not ready, Exchange touch probe battery, 1 error messages in the probing mode, 2 error messages during digitizing of 3d-contours

background image

SERVICE MANUAL TNC 415B/425

Page 85
Issue: 20.08.95

15.2 Error Messages

15.2.1 Error Messages in the Probing Mode

TOUCH POINT INACCESSIBLE

- After the start of a probing function, the scanning point was not reached within the measuring range defined

in the machine parameter MP6130.

EXCHANGE TOUCH PROBE BATTERY

- The battery voltage of the touch probe system with infrared transmission is below the minimum value.

STYLUS ALREADY IN CONTACT

- The stylus was already deflected when the probing function was started.

PROBE SYSTEM NOT READY

- The infrared transmission between the "Touch Probe" and the "Transmitter/Receiver Unit" is faulty

(e.g. caused by contamination) or interrupted. The two windows of the touch probe system must be
oriented to the transmitter/receiver unit.

- The battery is dead.
- The TM 110 is not connected.
- An error has been detected at one of the encoders of the TM110 (contamination).

15.2.2 Error Messages during Digitizing of 3D-Contours

WRONG AXIS PROGRAMMED

- The touch probe axis in the scanning cycle RANGE is not identical with the calibrated touch probe axis.

FAULTY RANGE DATA

- A MIN coordinate value in the scanning cycle RANGE is larger than or equal to the corresponding

MAX coordinate value.

- One or more coordinates are beyond the limit switch range of the scanning cycle RANGE.
- No scanning cycle RANGE was defined when calling the scanning cycles MEANDER or CONTOUR

LINES.

MIRRORING NOT PERMITTED

ROTATION NOT PERMITTED

SCALING FACTOR NOT PERMITTED

- Mirroring, rotation or scaling factor were active when the scanning cycles RANGE, MEANDER or

CONTOUR LINES were called.