Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Amplification for current controller
X
Y
Z
IV
V
S
2400.0
2400.1
2400.2
2400.3
2400.4
2400.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 30 000
[
1/V
]
0 = controller inhibited
0
0
0
0
0
0
reserved
X
Y
Z
IV
V
S
2410.0
2410.1
2410.2
2410.3
2410.4
2410.5
-
-
-
-
-
-
-
-
-
-
-
-
0
0
0
0
0
0
0
Proportional factor of the current
controller
X
Y
Z
IV
V
S
2500.0
2500.1
2500.2
2500.3
2500.4
2500.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 100 000[A
p
]
0
0
0
0
0
0
Integral factor of the current
controller
X
Y
Z
IV
V
S
2510.0
2510.1
2510.2
2510.3
2510.4
2510.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 100 000[A]
0
0
0
0
0
0
reserved
X
Y
Z
IV
V
S
2520.0
2520.1
2520.2
2520.3
2520.4
2520.5
-
-
-
-
-
-
-
-
-
-
-
-
0
0
0
0
0
0
0
reserved
X
Y
Z
IV
V
S
2530.0
2530.1
2530.2
2530.3
2530.4
2530.5
-
-
-
-
-
-
-
-
-
-
-
-
02
02
02
02
02
02
0
0
0
0
0
0
0
03.01.95
5.2
25