SERVICE MANUAL TNC 415B/425

Page 150
Issue: 20.08.95

The data can be read out as described in section 17.3.
The BACKUP routine is a very useful function to read out all data.
After pressing MOD in the operating mode "Machine Parameter Editing" (code number 95148)
the menu for interface configuration is displayed, comprising the soft keys

and

.

With

all operating parameters and the data of all file types are transferred via the data

interface and filed in $BACKUP.A. To reload the data into the TNC, press the soft key

.