Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Axes with encoder
X
Y
Z
IV
V
10
0
1
2
3
4
0 =
no encoder
+1 =
X axis with encoder
+2 =
Y axis with encoder
+4 =
Z axis with encoder
+8 =
IV. axis with encoder
+16 =
V. axis with encoder
% 11111
Encoder monitoring
Absolute position of distance-coded
reference marks
X
Y
Z
IV
V
S
30
0
1
2
3
4
5
0 =
no axis monitored
+1 =
X axis monitored
+2 =
Y axis monitored
+4 =
Z axis monitored
+8 =
IV. axis monitored
+16 =
V. axis monitored
+32 =
S axis monitored
% 111111
Signal amplitude
X
Y
Z
IV
V
S
31
0
1
2
3
4
5
0 =
no axis monitored
+1 =
X axis monitored
+2 =
Y axis monitored
+4 =
Z axis monitored
+8 =
IV. axis monitored
+16 =
V. axis monitored
+32 =
S axis monitored
% 111111
Edge separation
X
Y
Z
IV
V
S
32
0
1
2
3
4
5
0 =
no axis monitored
+1 =
X axis monitored
+2 =
Y axis monitored
+4 =
Z axis monitored
+8 =
IV. axis monitored
+16 =
V. axis monitored
+32 =
S axis monitored
% 111111