Range defined in mp1420.x), 1410.x, 1420.x – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 190

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Feed forward control or trailing
mode
in the operating modes
"Positioning with MDI"
"Program Run / Single Block"
"Program Run / Full Sequence"
1390
0 = feed forward control
1 = trailing mode
0
Feed forward control
in all operating modes
X
Y
Z
IV
V
1391
0
1
2
3
4
-
02
02
bit not set:
control in the operating modes "Positioning with
MDI", "Program Run / Single Block" and "Program
Run / Full Sequence" according to MP1390
bit set:
feed forward control in all operating modes
% 00000
Operation with Feed Forward Control
Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Position monitoring in operation
with feed forward control
cancellable (POSITIONING ERROR)
X
Y
Z
IV
V
1410.0
1410.1
1410.2
1410.3
1410.4
0.0001 to 30.0000 [mm]
3
3
3
3
3
EMERGENCY STOP
(GROSS POSITIONING ERROR)
X
Y
Z
IV
V
1420.0
1420.1
1420.2
1420.3
1420.4
0.0001 to 30.0000 [mm]
4
4
4
4
4
03.01.95
5.2
13