beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 180

background image

Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Assignment of the nominal value
outputs to the machine axes
(no function, if MP 2000.X

0)

X
Y

Z

IV

V

120.0
120.1
120.2
120.3
120.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0 to 5
0 =

output 1

1 =

output 2

2 =

output 3

3 =

output 4

4 =

output 5

5 =

output S

1)

0
1
2
3
4

Count direction of the encoder
signals

X
Y

Z

IV

V

210

0
1
2
3
4

Š

Š

Š

0 = positive
+1 = X axis negative
+2 = Y axis negative
+4 = Z axis negative
+8 = IV. axis negative
+16 = V. axis negative

(% 00000)

Signal period
(displacement per grating period; consider
the screw pitch when using a rotary
encoder.)
With square-wave input signals the
displacement per square-wave period
must be entered. (Consider external
interpolation.)

X
Y

Z

IV

V

330.0
330.1
330.2
330.3
330.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

I02
I02
I02
I02
I02

0.1 to 1000[µm]

20
20
20
20
20

Calculation of the signal period
Path for counting pulses from
MP 332.X

X
Y

Z

IV

V

331.0
331.1
331.2
331.3
331.4

-
-
-
-
-

-
-
-
-
-

02
02
02
02
02

0 to 99 999.9999 [mm]

0.02
0.02
0.02
0.02
0.02

Number of counting pulses from
MP 331.X

X
Y

Z

IV

V

332.0
332.1
332.2
332.3
332.4

-
-
-
-
-

-
-
-
-
-

02
02
02
02
02

1 to 16 177 215 [counting pulses]
The TNC automatically calculates the signal period.

signal period [mm] =

MP331

MP332

1
1
1
1
1

1)

S-analogue may only be used for a machine axis, if no analogue output of the spindle speed is required.

R H
1.0 TNC

415B/425

Machine Parameters

MP 120.0 - MP 332.4

03.01.95

5.2

3

This manual is related to the following products: