background image

Adaptation of the Data Interface

Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Inhibiting a data interface

5000

Š

Š

Š

0 =

no interface inhibited

1 =

RS-232 inhibited

2 =

RS-422 inhibited

0

Data format and transfer stop
operating mode EXT1
operating mode EXT2
operating mode EXT3 (PLC)

5020.0*
5020.1*
5020.2*

Š

Š

Š

Š

Š

Š

Š

Š

Š

0 to 255

168
168
168

7 or 8 data bits

0

+0 =

7 data bits, bit 8 = parity

+1 =

8 data bits, bit 8 = 0, bit 9 = parity

Block check character

1

+0 =

BCC character optional

+2 =

control character not BCC

Transmission stop through RTS

2

+0 =

inactive

+4 =

active

Transmission stop through DC3

3

+0 =

inactive

+8 =

active

Character parity even/odd

4

+0 =

even

+16 =

odd

Character parity on/off

5

+0 =

off

+32 = on

Number of stop bits

6

+ 64

bit 6 = 1

7

+128

bit 7 = 1

bit 6

bit 7

0

1 = 1½ stop bits

1

0 = 2 stop bits

0

1 = 1 stop bit

1

1 = 1 stop bit

* accessible via code number 123

R H
1.0 TNC

415B/425/426

Machine Parameters

MP 5000 - MP 5020.2

03.01.95

5.2