beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 199

background image

Table 1: Entry values depending on the power stage

The following SIEMENS power stages can be connected to TNC 426 PA:

6SN1123-1AA00

6SN1123-1AB00

0AA0

0BA0

0CA0

0DA0

0EA0

0FA0

0AA0

0BA0

0CA0

VSA

HSA

VSA

HSA

VSA

HSA

VSA

HSA

MP2110

14.14

25.45

50.91

50.91

79.2

79.2

158.4

158.4

198

198

14.14

25.45

50.91

MP2120

7.07

12.72

25.45

33.94

39.6

42.42

79.2

84.85

99

120.2

7.07

12.72

25.45

When using non-SIEMENS power stages, please contact HEIDENHAIN.

Table 2: Entry values depending on the motor

The following SIEMENS drives can be connected to TNC 426 PA:

1FT6064
6AC71

1FT6084
8AC71

1FT6086
8AC71

1FT6062
6AH71

1FT6082
8AH71

1PH6103
4NG4

1PH6107
4NG4

MP2200

0

0

0

0

0

1

1

MP2210

2 000

2 000

2 000

4 500

4 500

2 000

2 000

MP2220

2 915

3 080

2 970

6 435

6 930

9 900

9 900

MP2230

3

4

4

3

4

2

2

MP2280

0

0

0

0

0

14.0

22.1

MP2290

0

0

0

0

0

162

189

MP2300

5.4

11.8

15.4

5.5

11.5

28.3

43.8

MP2310

21.5

46.95

61.7

22.06

62.2

45.3

70.1

When using non-SIEMENS drives, please contact HEIDENHAIN.

R H

Tables for

1.0 TNC

415B/425/426

Machine Parameters

drive-dependent entry values

06.03.95

5.2

21.1

This manual is related to the following products: