Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Maximum current

1)

of the power stage

X
Y

Z

IV

V
S

2110.0
2110.1
2110.2
2110.3
2110.4
2110.5

-
-
-
-
-
-

-
-
-
-
-
-

Š

Š

Š

Š

Š

Š

0 to 999.999[A

p

]

e.g. with SIEMENS power stage 6SN1123-1AA00-
0BA0:

6SN1123-1AA00-0BA0:

18 A

x

2

= 25.45 Ap

see MP2310

0
0
0
0
0
0

Nominal current

1)

(reference value for I

2

t monitoring)

X
Y

Z

IV

V
S

2120.0
2120.1
2120.2
2120.3
2120.4
2120.5

-
-
-
-
-
-

-
-
-
-
-
-

Š

Š

Š

Š

Š

Š

0 to 999.999[Ap]
e.g.with SIEMENS power stage 6SN1123-1AA00-0BA0:

6SN1123-1AA00-0BA0:

9 A

x 2 = 12.72 Ap

0
0
0
0
0
0

Voltage of the current sensor
with peak current

X
Y

Z

IV

V
S

2130.0
2130.1
2130.2
2130.3
2130.4
2130.5

-
-
-
-
-
-

-
-
-
-
-
-

Š

Š

Š

Š

Š

Š

0 to 99.999[V]
with HEIDENHAIN interface card: 7.5V

0
0
0
0
0
0

Motor type

2)

X
Y

Z

IV

V
S

2200.0
2200.1
2200.2
2200.3
2200.4
2200.5

-
-
-
-
-
-

-
-
-
-
-
-

Š

Š

Š

Š

Š

Š

0 to 5
0 = synchronous motor
1 = asynchronous motor
2 to 5 = reserved

0
0
0
0
0
0

1)

entry values depending on the power stage: see table 1 on page 21.1

2)

entry values depending on the motor: see table 2 on page 21.1