Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Maximum current
1)
of the power stage
X
Y
Z
IV
V
S
2110.0
2110.1
2110.2
2110.3
2110.4
2110.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 999.999[A
p
]
e.g. with SIEMENS power stage 6SN1123-1AA00-
0BA0:
6SN1123-1AA00-0BA0:
18 A
x
2
= 25.45 Ap
see MP2310
0
0
0
0
0
0
Nominal current
1)
(reference value for I
2
t monitoring)
X
Y
Z
IV
V
S
2120.0
2120.1
2120.2
2120.3
2120.4
2120.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 999.999[Ap]
e.g.with SIEMENS power stage 6SN1123-1AA00-0BA0:
6SN1123-1AA00-0BA0:
9 A
x 2 = 12.72 Ap
0
0
0
0
0
0
Voltage of the current sensor
with peak current
X
Y
Z
IV
V
S
2130.0
2130.1
2130.2
2130.3
2130.4
2130.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 99.999[V]
with HEIDENHAIN interface card: 7.5V
0
0
0
0
0
0
Motor type
2)
X
Y
Z
IV
V
S
2200.0
2200.1
2200.2
2200.3
2200.4
2200.5
-
-
-
-
-
-
-
-
-
-
-
-
0 to 5
0 = synchronous motor
1 = asynchronous motor
2 to 5 = reserved
0
0
0
0
0
0
1)
entry values depending on the power stage: see table 1 on page 21.1
2)
entry values depending on the motor: see table 2 on page 21.1