HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 219

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Operating mode for
EXT1
EXT2
EXT3 (PLC)
5030.0*
5030.1*
5030.2*
0 =
"standard data transfer"
1 =
"blockwise transfer"
1
1
1
Data transfer rate for PLC coupling
(EXT3)
5040
0 to 9
0 = 110 Bd
5 = 2400 Bd
1 = 150 Bd
6 = 4800 Bd
2 = 300 Bd
7 = 9600 Bd
3 = 600 Bd
8 = 19200 Bd
4 = 1200 Bd
9 = 38400 Bd
7
Control characters for "Blockwise
Transfer"
ASCII character for beginning of
program
EXT1
EXT2
EXT3 (PLC)
(STX)
5200.0*
5200.1*
5200.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for end of program
EXT1
EXT2
EXT3 (PLC)
(ETX)
5201.0*
5201.1*
5201.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for file type (for
data transfer)
EXT1
EXT2
EXT3 (PLC)
5202.0*
5202.1*
5202.2*
I02
I02
I02
0 to 127
0
0
0
* accessible via code number 123
06.03.95
5.2
41
This manual is related to the following products: