beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 17

background image

SERVICE MANUAL TNC 415B/425

Page

14

Issue: 20.08.95

Display (blinking)

Error Cause

ENCODER DEFECTIVE YA

ENCODER ` DEFECTIVE YA

ENCODER DEFECTIVE YB

ENCODER ` DEFECTIVE YB

ENCODER DEFECTIVE YC

ENCODER `DEFECTIVE YC

Signal amplitude error position encoder

Signal amplitude error speed encoder

Signal frequency error position encoder

Signal frequency error speed encoder

Error with distance-coded scale position encoder

Error with distance-coded scale speed encoder

Y = CPU number 1 = main processor

2 = geometry processor
3 = CLP processor

Error Causes:
- Encoder not connected
- Cable damaged
- Glass scale contaminated or damaged
- Scanning head defective
- Encoder monitoring system defective

Checking the encoders: see section 13

WRONG REFERENCE POINT

TNC OPERATING TEMP. EXCEEDED

EMERG. STOP DEFECTIVE YX

EMERGENCY STOP PLC

Wrong reference mark spacing entered with distance-
coded linear encoders (counting error caused by the
measuring system or the logic unit)

Temperature inside the logic unit has exceeded + 70°C

YX = 1( 1. emergency stop test

1) 2. emergency stop test
1. 3. emergency stop test

- Error during the test routine "Control ready for operation"

when the machine is switched on (see section 19.4)

This error message is only generated, if the marker 2815
is set without additional marker (M2924 - M3023).

This manual is related to the following products: