17.2 Overview of Files for TNC 415B/425

Depending on the subordinate mode (NC, PLC MODE, MP MODE etc.) in which the transfer menu is
activated, only certain file types are offered to be downloaded or output.

The following data may be in the RAM:

NC Memory Management

Extension

(TNC)

Extension

(external)

NC program: HEIDENHAIN language
NC program: ISO
Active tool file
Tool data (table)
Pocket number table
Pallet table
Datum table
Text file (ASCII)
Measuring point table (digitizing)

.H

.I

TOOL.T

.T

.P

.D

.A

.PNT

.H
.D

TOOL.T

.T

TOOL_P.R

.L

.N

.A

.U

PLC Memory Management (RAM)
PLC program
Error messages1. language
Error messagesEnglish
Dialogues

1. language

Dialogues

English

ASCII file
Help texts
Data for axis error compensation
Data for axis error compensation

.PLC
.ER1

.ERE

.DI1

.DIE

.A

.HLP

.COM

.CMA

.P

.A
.A
.A
.A
.A

.J

.V
.S

Machine Parameter Mode
Machine parameter lists

.MP

.M

Compensation value table
selectable via code number

.KOR

.S

Additional information on the files or programs is provided by letters in the status field.

E:

The file/program has been selected in the PROGRAMMING mode.

S:

The file/program has been selected and activated in the TEST RUN mode.

M: The file/program has been selected and activated in either PROGRAM RUN / FULL SEQUENCE

or in PROGRAM RUN / SINGLE BLOCK.

P:

The file/program is protected against erasing and editing.

IN: The table/program was programmed in Inch.
W: The file/program was not completely transferred to an external memory and thus is no longer available.

17.3 External Data Output

Preparations:

-

Connect the external data medium (FE, ME or other peripheral unit, e.g. personal computer with
HEIDENHAIN data transfer software) to the TNC.

-

Prepare the external data medium for data transfer:

Press

STOP

,

TNC

and

at the ME

Press

STOP

at the FE.

-

Select the operating mode, the baud rate and the interface assignment at the TNC (see section 16.1).