HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 32

SERVICE MANUAL TNC 415B/425
Page 29
Issue: 20.08.95
6.2.2 Pin Layout: PL 400
X1
Pin No.
Assignment
as 1. PL
as 2. PL
X4
Pin No.
Assignment
as 1. PL
as 2. PL
1
O32
064
1
I126
I254
2
O33
065
2
I74
I202
3
O34
066
3
I73
I201
4
O35
067
4
I72
I200
5
O36
068
5
I71
I199
6
O37
069
6
I70
I198
7
O38
070
7
I69
I197
8
O39
071
8
I68
I196
9
O40
072
9
I67
I195
10
O41
073
10
I66
I194
11
O42
074
11
I65
I193
12
do not assign
12
I64
I192
X2
Pin No.
Assignment
as 1. PL
as 2. PL
X5
Pin No.
Assignment
as 1. PL
as 2. PL
1
O43
075
1
I86
I214
2
O44
076
2
I85
I213
3
O45
077
3
I84
I212
4
O46
078
4
I83
I211
5
O47
079
5
I82
I210
6
O48
080
6
I81
I209
7
O49
081
7
I80
I208
8
O50
082
8
I79
I207
9
O51
083
9
I78
I206
10
O52
084
10
I77
I205
11
O53
085
11
I76
I204
12
do not assign
12
I75
I203
X3
Pin No.
Assignment
as 1. PL
as 2. PL
X6
Pin No.
Assignment
as 1. PL
as 2. PL
1
O54
086
1
I98
I227
2
O55
087
2
I97
I226
3
O56
1)
088
1)
3
I96
I225
4
O57
1)
089
1)
4
I95
I224
5
O58
1)
090
1)
5
I94
I223
6
O59
1)
091
1)
6
I93
I221
7
O60
1)
092
1)
7
I93
I220
8
O61
1)
093
1)
8
I91
I219
9
O62
1)
094
1)
9
I90
I218
10
control ready for operation
10
I89
I217
11
do not assign
11
I88
I216
12
+24V cannot be switched off
12
I87
I215
via ext. EMERG. STOP
1)
outputs cannot be switched off via ext. EMERG. STOP