beautypg.com

Range defined in mp1720.x), 1710.x, 1720.x – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 193

background image

Operation with Servo Lag

Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Position monitoring during
operation with servo lag
cancellable (POSITIONING ERROR)

X
Y

Z

IV

V

1710.0
1710.1
1710.2
1710.3
1710.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0 to 300 [mm]

20
20
20
20
20

EMERGENCY STOP
(GROSS POSITIONING ERROR)

X
Y

Z

IV

V

1720.0
1720.1
1720.2
1720.3
1720.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0 to 300 [mm]

30
30
30
30
30

1. block of Kv factors
for the trailing mode

X
Y

Z

IV

V

1810.0
1810.1
1810.2
1810.3
1810.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.1 to 10

1
1
1
1
1

2. block of Kv factors for the
trailing mode
M105: enable
M106: inhibit

X
Y

Z

IV

V

1815.0
1815.1
1815.2
1815.3
1815.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.1 to 10

1
1
1
1
1

R H
1.0 TNC

415B/425

Machine Parameters

MP 1710.0 - MP 1815.4

03.01.95

5.2

16

This manual is related to the following products: