7290.x – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 234

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Display of the feed rates in the
MANUAL operating modes
7270
*
0 =
display of the axis feed rate only when an axis-
direction key is pressed (axis-specific feed rate
from MP1020.X)
1 =
display of the axis feed rate before operating an
axis-direction key (smallest value from MP1020.X
for all axes)
0
Decimal sign
7280*
0 = decimal comma
1 = decimal point
0
Tool length in nominal / actual
value display
7285*
0 = tool length ignored
1 = tool length taken into account
0
Display step
X
Y
Z
IV
V
7290.0
*
7290.1
*
7290.2
*
7290.3
*
7290.4
*
0 = 0.1 mm or 0.1°
1 = 0.05 mm or 0.05°
2 = 0.01 mm or 0.01°
3 = 0.005 mm or 0.005°
4 = 0.001 mm or 0.001°
5 = 0.0005 mm or 0.0005°
6 = 0.0001 mm or 0.0001°
6
6
6
6
6
Inhibiting datum setting
(axis keys and soft key)
X
Y
Z
IV
V
7295*
0
1
2
3
4
0 = not disabled
+ 1 = X axis disabled
+ 2 = Y axis disabled
+ 4 = Z axis disabled
+ 8 = IV axis disabled
+16 = V axis disabled
0
Datum setting with axis keys
7296
08
0 = datum can be set with axis keys and soft key
1 = datum can be set with soft key only
0
* accessible via code number 123
06.03.95
5.2
56