10.4 Power Supply of the PLC

The power supply line for the internal PLC of LE 415B/425 is connected to the terminal strip X44.

X44 PLC power supply of LE 415B/425

Terminal strip (pluggable) 3-pin

Pin No.

Assignment

1

+ 24 V_A, can be switched off
via EMERGENCY STOP

2

+ 24 V , cannot be switched off
via EMERGENCY STOP

3

0V

Fuses:

F1: 3.15A (+ 24V_A, can be switched off)
F2: 1.0A (+ 24V, cannot be switched off)

The PLC power supply of PL 400, PL 405, PL 410 or PA 110 is connected to the following terminal strips:

Power supply of PA 110

Pin No.

Assignment

1

+ 24 V - can be switched off via
EMERGENCY STOP

2

0V

Power supply of PL 400

Terminal

Assignment

X13

+ 24 V can be switched off via
EMERGENCY STOP

X12

0V

X3, pin 12

+ 24V_A cannot be switched off
via EMERGENCY STOP

Power supply of PL 405 / 410

X9, X10, X11, X12, X13, X14
Power supply of PL

Terminal

Assignment

1.PL

2.PL

X9

0V

X10

+ 24V- logic unit and "control ready for operation"

X11 1)

+ 24V- logic unit for outputs

O32 - O39

O64 - O71

X12 1)

+ 24V- logic unit for outputs

O40 - O47

O72 - O79

X13

+ 24V- logic unit for outputs

O48 - O55

O80 - O87

X14

+ 24V- logic unit for outputs

O56 - O62

O88 - O94

Fuse:

- F2: T1A (+ 24V- supply for logic unit)

1)

not with PL 405