17.3.3 Output of the Machine Parameter List
NOTE:
The TNC only displays the external directory in the FE1 mode.
Press Key
Function
MOD
9
5
1
4
8
ENT
MOD
EXT
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Here an interface can be allocated to the MP editor
Activate data transfer menu
There may be several files with the extension .MP in the TNC. The active machine parameter list is distinguished
by the STATUS M.
END
Soft key for data transfer
Exit data transfer menu
TNC in operating mode PROGRAMMING AND EDITING