Control. (can be influenced via mp1140.x), Machine parameter mp1110.x, An automatic offset adjustment with mp1220 – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 188: 1140.x

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Acceleration
X
Y
Z
IV
V
1060.0
1060.1
1060.2
1060.3
1060.4
0.001 to 3.0 [m/s²]
1
1
1
1
1
Radial acceleration
1070
0.0001 to 3.0 [m/s²]
1.5
Integral factor
1)
X
Y
Z
IV
V
1080.0
1080.1
1080.2
1080.3
1080.4
0 to 65 535
0
0
0
0
0
Standstill monitoring
X
Y
Z
IV
V
1110.0
1110.1
1110.2
1110.3
1110.4
0.0001 to 30 [mm]
0.1
0.1
0.1
0.1
0.1
0.1
Movement monitoring
X
Y
Z
IV
V
1140.0
1140.1
1140.2
1140.3
1140.4
0.03 to 10 [V] for TNC 415B/425
1)
0.03 to 10 [1000/min] for TNC 426 PA
Note: entry value 10
Ö monitoring inactive
1
1
1
1
1
1
Time out to switch off the residual
voltage on error message "Positioning
Error"
1150
0 to 65 535 [s]
0
Automatic cyclical
2)
offset adjustment
1220
1 to 65 535 [s]
0 = no automatic adjustment
1
1)
analogue controlled
2)
no function with TNC 425 (MP 1900
≠
0) and TNC 426 PA (MP 2000
≠
0): entry value = 0
06.03.95
5.2
11