Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Acceleration

X
Y

Z

IV

V

1060.0
1060.1
1060.2
1060.3
1060.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.001 to 3.0 [m/s²]

1
1
1
1
1

Radial acceleration

1070

Š

Š

Š

0.0001 to 3.0 [m/s²]

1.5

Integral factor

1)

X
Y

Z

IV

V

1080.0
1080.1
1080.2
1080.3
1080.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0 to 65 535

0
0
0
0
0

Standstill monitoring

X
Y

Z

IV

V

1110.0
1110.1
1110.2
1110.3
1110.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.0001 to 30 [mm]

0.1
0.1
0.1
0.1
0.1
0.1

Movement monitoring

X
Y

Z

IV

V

1140.0
1140.1
1140.2
1140.3
1140.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.03 to 10 [V] for TNC 415B/425

1)

0.03 to 10 [1000/min] for TNC 426 PA
Note: entry value 10

Ö monitoring inactive

1
1
1
1
1
1

Time out to switch off the residual
voltage on error message "Positioning
Error"

1150

Š

Š

Š

0 to 65 535 [s]

0

Automatic cyclical

2)

offset adjustment

1220

Š

Š

Š

1 to 65 535 [s]
0 = no automatic adjustment

1

1)

analogue controlled

2)

no function with TNC 425 (MP 1900

0) and TNC 426 PA (MP 2000

0): entry value = 0

R H
1.0 TNC

415B/425

Machine Parameters

MP1060.0 - MP 1220

06.03.95

5.2

11