HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 217

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
PLC: setting a number
(readable with module 9032)
4231.0
.
.
.
4231.31
.
.
.
.
.
.
.
.
.
-99 999.9999 to +99 999.9999
0
-
-
-
0
PLC: setting a number
W976
(M2192 to 2207)
W978
(M2208 to 2223)
W980
(M2224 to 2239)
W982
(M3200 to 3215)
W984
(M3216 to 3231)
W986
(M3232 to 3247)
W990
(M3248 to 3263)
4310.0
4310.1
4310.2
4310.3
4310.4
4310.5
4310.6
-99 999.9999 to +99 999.9999
20480
0
0
0
0
0
0
Adaptation of the PLC extension
interface (X47)
4410
0
1
1)
+0 = no analogue inputs activated on
1. extension
+1 = analogue inputs on 1. extension (PA 100
or analogue inputs activated on PL 410)
+0 = no analogue inputs activated on
2. extension
+2 = analogue inputs on 2. extension (PA 100
or analogue inputs activated on PL 410)
0
1)
reserved, entry value 0
03.01.95
5.2