beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 196

background image

Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Factor for acceleration feedforward
control of the speed controller

X
Y

Z

IV

V

1945.0
1945.1
1945.2
1945.3
1945.4

Š

Š

Š

Š

Š

0 to 9.999 [V/(m/s²)]

0
0
0
0
0

Polarity of torque signal

X
Y

Z

IV

V

1950

0
1
2
3
4

Š

Š

0 to 31
0 =

positive

+1 =

X axis negative

+2 =

Y axis negative

+ 4 = Z axis negative
+ 8 =

IV. axis negative

+ 16 = V. axis negative

% 00000

Selecting the measuring systems

X

Y

Z

IV

V

1951

0

1
2
3
4

Š

Š

0 to 31
0 =

2 measuring systems for each axis:
- linear encoder for position
- rotary encoder for speed

+1 =

1 measuring system (rotary encoder) for both
position and speed (X axis)

+2 =

Y axis

+4 =

Z axis

+8 =

IV. axis

+16 = V. axis

% 00000

Ratio of grating period
LS to ROD

X
Y

Z

IV

V

1955.0
1955.1
1955.2
1955.3
1955.4

Š

Š

Š

Š

Š

Š

Š

Š

Š

Š

0.1 to 100

(the entry values should be >5)

1
1
1
1
1

R H
1.0 TNC

415B/425

Machine Parameters

MP 1945.0 - MP 1955.4

03.06.96

5.2

19