SERVICE MANUAL TNC 415B/425

Page 108
Issue: 20.08.95

17.3.6 Output of Files from PLC Memory

NOTE:
The TNC only displays the external directory in the FE1 mode.

Overview of the Files

PLC programs
Error messages

1. language

Error messages

English

Dialogues 1.

language

Dialogues English
ASCII files
Help texts
Files for axis error compensation
Files for axis error compensation

.PLC
.ER1

1)

.ERE

1)

.DI1

1)

.DIE

1)

.A

1)

.HLP
.COM

2)

.CMA

2)

1)

Note:
The error messages, dialogues and ASCII files are output as ASCII files with the extension .A.
Therefore, the files to be output must have different filenames so that they will not be overwritten
on the external data medium.

(to rename a files, press the soft key

.)

Note down filename and the extension!

After having downloaded the files, the extension .A must be reconverted to the original extension

by pressing the soft key

.

2)

see section 17.3.4

*

There may be several files with the same extension in RAM.
Note down status information (see section 17.2).