SERVICE MANUAL TNC 415B/425

Page 34
Issue: 20.08.95

6.2.6 Pin Layout: PL 410

X1 Connection to Logic Unit or

to 1. PL

X2 Connection of 2. PL or PA

Pin No.

Assignment

Pin No.

Assignment

1,2,3

0V

1,2,3

0V

5, 6, 17, 18

do not assign

4-6, 14 - 18

do not assign

4

serial IN 2

7

RESET

7

-RESET

8

-WRITE EXTERN

8

-WRITE EXTERN

9

WRITE EXTERN

9

WRITE EXTERN

10

-O5

10

-O5

11

-O3

11

-O3

12

-O1

12

-O1

13

shield

13

shield

19

serial IN 2

14, 15

+12V

20

control ready for operation

16

board ID (PK)

21

-serial OUT

19

serial IN 1

22

serial OUT

20

control ready for operation

23

-O4

21

-serial OUT

24

-O2

22

serial OUT

25

-O0

23

-O4

24

-O2

25

-O0

X3 PLC Inputs

X4 PLC Inputs

Pin No.

Assignment
as 1. PL

as 2. PL

Pin No.

Assignment
as 1. PL

as 2. PL

1

I64

I192

1

I80

I208

2

I65

I193

2

I81

I209

3

I66

I194

3

I82

I210

4

I67

I195

4

I83

I211

5

I68

I196

5

I84

I212

6

I69

I197

6

I85

I213

7

I70

I198

7

I86

I214

8

I71

I199

8

I87

I215

9

I72

I200

9

I88

I216

10

I73

I201

10

I89

I217

11

I74

I202

11

I90

I218

12

I75

I203

12

I91

I219

13

I76

I204

13

I92

I220

14

I77

I205

14

I93

I221

15

I78

I206

15

I94

I222

16

I79

I207

16

I95

I223