HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 38

SERVICE MANUAL TNC 415B/425
Page 35
Issue: 20.08.95
X5 PLC Inputs
X6 PLC Inputs
Pin No.
Assignment
as 1. PL
as 2. PL
Pin No.
Assignment
as 1. PL
as 2. PL
1
I96
I224
1
I112
I240
2
I97
I225
2
I113
I241
3
I98
I226
3
I114
I242
4
I99
I227
4
I115
I243
5
I100
I228
5
I116
I244
6
I101
I229
6
I117
I245
7
I102
I230
7
I118
I246
8
I103
I231
8
I119
I247
9
I104
I232
9
I120
1)
I248
1)
10
I105
I233
10
I121
1)
I249
1)
11
I106
I234
11
I122
1)
I250
1)
12
I107
I235
12
I123
1)
I251
1)
13
I108
I236
13
I124
1)
I252
1)
14
I109
I237
14
I125
1)
I253
1)
15
I110
I238
15
I126
1)
I254
1)
16
I111
I239
16
I127
1)
I255
1)
X7 PLC Outputs
X8 PLC Outputs
and "Control Ready for Operation"
Pin No.
Assignment
as 1. PL
as 2. PL
Pin No.
Assignment
as 1. PL
as 2. PL
1
O32
O64
1
O48
O80
2
O33
O65
2
O49
O81
3
O34
O66
3
O50
O82
4
O35
O67
4
O51
O83
5
O36
O68
5
O52
O84
6
O37
O69
6
O53
O85
7
O38
O70
7
O54
O86
8
O39
O71
8
O55
O87
9
O40
O72
9
O56
O88
10
O41
O73
10
O57
O89
11
O42
O74
11
O58
O90
12
O43
O75
12
O59
O91
13
O44
O76
13
O60
O92
14
O45
O77
14
O61
1)
O93
1)
15
O46
O78
15
O62
1)
O94
1)
16
O47
O79
16
control ready for operation
1)
With active analogue inputs (depend on the position of the ENABLE ANALOGUE INPUTS switch on
PL140) these PLC inputs and outputs are not available (see section 21.7.2).