HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 229

Display and Programming
Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Programming station
7210*
0 = control
1 = programming station: PLC active
2 = programming station: PLC inactive
0
POWER INTERRUPTED
7212
0 =
press [CE] to confirm the message
1 =
message is confirmed automatically
1
Block number increment size
(for ISO programming)
7220*
0 to 250
0 =
no generation
0
Maximum length of file names
when opening a file
7222*
I02
0 =
max. 8 characters
1 =
max. 12 characters
2 =
max. 16 characters
Disabling file types
(for selection, table of contents and ext.
data transfer)
7224.0*
0 =
no file type disabled
% 00000000
HEIDENHAIN programs
(.H)
0
+ 1 =
disabled
ISO programs
(.I)
1
+ 2 =
disabled
Tool tables
(.T)
2
+ 4 =
disabled
Datum tables
(.D)
3
+ 8 =
disabled
Pallet tables
(.P)
4
+16 =
disabled
ASCII (text) files
(.A)
5
+32 =
disabled
PLC help files
(.HLP)
6
08
+64 =
disabled
Measuring point tables
(.PNT)
7
08
+128 = disabled
* accessible via code number 123
03.01.95
5.2
51