HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 226

Tool Calibration with TT 110
Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Tool calibration cycles
6500
-
0 = cycles inhibited
1 = cycles not inhibited
0
Probing direction for tool
calibration
6505
-
0 = pos. probing direction in the angle
reference axis (0° axis)
1 =
pos. probing direction in the +90° axis
2 =
neg. probing direction in the angle
reference axis (0° axis)
3 = neg. probing direction in the +90° axis
0
Calculating the probing feed rate
6507
-
0 = calculation of probing feed rate with constant
tolerance
1 =
calculation of probing feed rate with variable
tolerance
2 =
constant probing feed
0
Maximum permissible measuring
error
for measurement with a rotating tool
6510
-
0.002 to 0.999 [mm]
0.005
Probing feed rate
for measurement with a non-rotating tool
6520
-
10 to 3 000 [mm/min]
10
Distance between lower edge of
tool and upper edge of stylus
for tool radius measurement
6530
-
0.001 to 99.9999 [mm]
10
Diameter or edge length of the
TT 110 stylus
6531
-
0.001 to 99 999.9999 [mm]
10
03.01.95
5.2
48