beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 226

background image

Tool Calibration with TT 110

Function

MP

No.

Bit

A

B

C

Input

AE-6

Entry value

Tool calibration cycles

6500

-

Š

Š

0 = cycles inhibited
1 = cycles not inhibited

0

Probing direction for tool
calibration

6505

-

Š

Š

0 = pos. probing direction in the angle

reference axis (0° axis)

1 =

pos. probing direction in the +90° axis

2 =

neg. probing direction in the angle
reference axis (0° axis)

3 = neg. probing direction in the +90° axis

0

Calculating the probing feed rate

6507

-

Š

Š

0 = calculation of probing feed rate with constant

tolerance

1 =

calculation of probing feed rate with variable
tolerance

2 =

constant probing feed

0

Maximum permissible measuring
error
for measurement with a rotating tool

6510

-

Š

Š

0.002 to 0.999 [mm]

0.005

Probing feed rate
for measurement with a non-rotating tool

6520

-

Š

Š

10 to 3 000 [mm/min]

10

Distance between lower edge of
tool and upper edge of stylus
for tool radius measurement

6530

-

Š

Š

0.001 to 99.9999 [mm]

10

Diameter or edge length of the
TT 110 stylus

6531

-

Š

Š

0.001 to 99 999.9999 [mm]

10

R H
1.0 TNC

415B/425/426

Machine Parameters

MP 6500 - MP 6531

03.01.95

5.2

48

This manual is related to the following products: