X9, X10, X11, X12, X13, X14 PL Power Supply
Terminal
Assignment
as 1. PL
as 2. PL
X9
0V
X10
+24 V- supply of LE and "Control Ready for Operation"
X11
+24 V- output supply
O32 - O39
O64 - O71
X12
+24 V- output supply
O40 - O47
O72 - O79
X13
+24 V- output supply
O48 - O55
O80 - O87
X14
+24 V- output supply
O56 - O62
O88 - O94
X15
1)
, X16
1)
, X17
1)
, X18
1)
Analogue Inputs
±
10V
Pin No.
Assignment
1
voltage input (
±
10V)
2
0V
3
shield
X19
1)
, X20
1)
, X21
1)
, X22
1)
Inputs for PT 100
Thermistors
Four-wire Connector with constant current source
Pin No.
Assignment
1
I+
constant current for PT 100
2
U+
measuring input
3
U-
measuring input
4
I-
constant current for PT 100
5
shield
Allocation of Analogue Inputs to Internal PLC Memory Addresses
Input
Internal Memory Address
1. PL 410
2. PL 410
X15
W496
W464
X16
W498
W466
X17
W500
W468
X18
W502
W470
X19
W504
W472
X20
W506
W474
X21
W508
W476
X22
W510
W478
1)
not with version 11 of PL 410