beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 39

background image

SERVICE MANUAL TNC 415B/425

Page 36
Issue: 20.08.95

X9, X10, X11, X12, X13, X14 PL Power Supply

Terminal

Assignment

as 1. PL

as 2. PL

X9

0V

X10

+24 V- supply of LE and "Control Ready for Operation"

X11

+24 V- output supply

O32 - O39

O64 - O71

X12

+24 V- output supply

O40 - O47

O72 - O79

X13

+24 V- output supply

O48 - O55

O80 - O87

X14

+24 V- output supply

O56 - O62

O88 - O94

X15

1)

, X16

1)

, X17

1)

, X18

1)

Analogue Inputs

±

10V

Pin No.

Assignment

1

voltage input (

±

10V)

2

0V

3

shield

X19

1)

, X20

1)

, X21

1)

, X22

1)

Inputs for PT 100

Thermistors
Four-wire Connector with constant current source

Pin No.

Assignment

1

I+

constant current for PT 100

2

U+

measuring input

3

U-

measuring input

4

I-

constant current for PT 100

5

shield

Allocation of Analogue Inputs to Internal PLC Memory Addresses

Input

Internal Memory Address

1. PL 410

2. PL 410

X15

W496

W464

X16

W498

W466

X17

W500

W468

X18

W502

W470

X19

W504

W472

X20

W506

W474

X21

W508

W476

X22

W510

W478

1)

not with version 11 of PL 410