Spindle – HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 205

Spindle
Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Output of the spindle speed
3010
0 =
spindle speed not output
6
coded
1 =
only if speed changes
2 =
with every TOOL CALL
analogue
3 =
gear switching signal only if gear range
changes
4 =
gear switching signal with every
TOOL CALL
5 =
no gear switching signal
controlled spindle for orientation
6 =
gear switching signal only if gear range
changes
7 =
gear switching signal with every
TOOL CALL
8 =
no gear switching signal
Output of an analogue voltage at
the analogue output of the spindle
(only if MP3010 < 3)
3011
-
0 =
no function
1 =
voltage is proportional to the current feed
rate
2 =
voltage defined via PLC (module 9130)
3 =
voltage defined via M-function
(M200 - M204)
0
Feed rate that corresponds to an
analogue voltage of 10V
(only if MP3011 = 1)
3012
0 to 300 000 [mm/min]
0
06.03.95
5.2
27