19.3.2 PLC Outputs

The PLC outputs can be checked as follows:

Connect the test unit between the PLC and the LE (measure directly at the PL boards).

Press Key

Function

MOD

8

0

7

6

6

7

ENT

TNC in operating mode PROGRAMMING/EDITING

Prepare TNC for input of code number

Enter code number, confirm with ENT

Call TABLE function

Display of output table

Now the logic states of the outputs are displayed on the screen. They must correspond to the voltage levels
of the corresponding outputs. If there is a difference, check the output cable for short circuit and measure
the output current at the interface (max. 100 mA for LE outputs, max. 1.2 A for PL outputs). If the output
current is not exceeded and connecting cable is in order, the output board of the PLC graphics board or the
PLC I/O board PL 400/405/410 is defective.

Exit the TABLE function

TNC in operating mode PROGRAMMING/EDITING

*

Observe the safety instructions!