beautypg.com

HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual

Page 82

background image

SERVICE MANUAL TNC 415B/425

Page 77
Issue: 20.08.95

Flow-Chart for Error Location

ENCODER X DEFECTIVE 3B

(Example)

Defect is located in the position
encoder input of the control

Defect is located in the position
encoder or in the encoder cable

*

Observe the safety instructions!

switch off power

switch encoder of X axis

and e.g. encoder of Y axis

at the logic unit

switch on power

if the message

POWER INTERRUPTED

is generated, enter code number

95148 to call the active parameter

list and switch the entry values

of MP110.0 and 110.1

Does the error message

switch from X to Y?

YES

NO