HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 132

SERVICE MANUAL TNC 415B/425
Page 127
Issue: 20.08.95
b) Cyclic Offset Adjustment via Machine Parameters
In the machine parameter MP1220 the cycle time is defined [1s] after which an offset is compensated
by one converter step.
To switch off the automatic offset adjustment, enter the value 0 in the machine parameter MP1220.
*
NOTE:
If an offset voltage of 100 mV is reached with automatic offset adjustment, the control switches off,
generating the error message
GROSS POSITIONING ERROR
c) Offset Adjustment at the Servo Amplifier
•
Check and adjust the following machine parameters. (Note down the original values before changing.)
MP
Entry Value
Function
Original Entry
Value
1080.0
1080.1
1080.2
1080.3
1080.4
0
0
0
0
0
integral factor
0
cycle time for
automatic offset adjustment
0
feed forward control ON
1510.0
1510.1
1510.2
1510.3
1510.4
≥
1
≥
1
≥
1
≥
1
≥
1
KV factor for feed forward control
6
display step = 0.1 µm
Switch position display to LAG (display of servo lag); see section 18.3.
•
Cancel the offset compensation with code number (see item a)
•
Reset the machine parameter values and the position display to their original values.
18.5.2 Axes with Integral Digital Speed Controller
With axes with integral digital speed controller (TNC 425, corresponding bit of MP1900 = 1)
the offset adjustment as described in section 18.5.1 is not required.
.