HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 41

SERVICE MANUAL TNC 415B/425
Page 38
Issue: 20.08.95
6.2.8 Pin Layout: PA 110
X1 Connection to Logic Unit or
1.PL
X2, X3, X4, X5
Analogue Inputs
±
10V
Pin No.
Assignment
Pin No.
Assignment
1, 2, 3
0 V
1
voltage input (+/- 10 V)
4
serial IN 2
2
0 V
5, 6, 17, 18
do not assign
3
shield
7
-RESET
8
-WRITE EXTERN
9
WRITE EXTERN
X6 PA 110 Power Supply
10
-O5
Pin No.
Assignment
11
-O3
1
+24 V
12
-O1
2
0V
13
shield
14, 15
+ 12V
16
board ID (PK)
19
serial IN 1
X7, X8, X9, X10 Inputs for PT 100
20
control ready for operation
Thermistors
21
-serial OUT
Four-wire connector with const. current source
22
serial OUT
Pin No.
Assignment
23
-O4
1
I+
constant current for PT100
24
-O2
2
U+
measuring input
25
-O0
3
U-
measuring input
4
I-
constant current for PT100
5
shield
Allocation of Analogue Inputs to Internal PLC Memory Addresses
Input
Internal Memory Address
PA as 1. expansion
PA as 2. expansion
X2
W496
W464
X3
W498
W466
X4
W500
W468
X5
W502
W470
X7
W504
W472
X8
W506
W474
X9
W508
W476
X10
W510
W478