HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 224

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Deflection depth of stylus
6300
1)
10
-
-
0.1 to 2.0000 [mm]
1
Deflection depth of stylus
6310
-
0.1 to 2.0000 [mm]
1
Counting direction of the encoders
in the touch probe
X
Y
Z
6320
0
1
2
10
10
0 = positive
+1 = X axis negative
+2 = Y axis negative
+4 = Z axis negative
0
Calculating the center offset when
calibrating the TM 110
6321
-
0 = calibrate and measure center offset
1 = calibrate without measuring center offset
0
Allocation of the touch probe axes
to the machine axes
machine axis
machine axis
machine axis
X
Y
Z
6322.0
6322.1
6322.2
-
-
-
0 = touch probe axis X
1 = touch probe axis Y
2 = touch probe axis Z
0
1
2
Maximum deflection of the stylus
6330
10
10
0.1 to 4 [mm]
3
Minimum deflection of the stylus
6340
I12
I12
-
0.001 to 0.5 [mm]
0.005
Feed rate for positioning to the MIN
point and contour approach
6350
10
10 to 3 000 [mm/min]
300
Feed rate for probing in measuring
cycles
6360
10
10 to 3 000 [mm/min]
1000
Rapid traverse for probing
6361
10
10 to 10 000 [mm/min]
2000
Feed rate reduction
if the stylus (TM 110) is deflected away
from its path
6362
-
0 = feed reduction inactive
1 = feed reduction active
0
1)
with special software and for TNC 426 this function has been shifted to MP 6310!
06.03.95
5.2
46