HEIDENHAIN TNC 415 (259 9x0) Service Manual User Manual
Page 230

Function
MP
No.
Bit
A
B
C
Input
AE-6
Entry value
Protecting file types
7224.1*
0 =
no file type protected
% 00000000
HEIDENHAIN programs
(.H)
0
+ 1 = protected
ISO programs
(.I)
1
+ 2 = protected
Tool tables
(.T)
2
+ 4 = protected
Datum tables
(.D)
3
+ 8 = protected
Pallet tables
(.P)
4
+16 = protected
ASCII (text) files
(.A)
5
+32 = protected
PLC help files
(.HLP)
6
08
+64 = protected
Measuring point tables
(.PNT)
7
08
+128 = protected
Preset size
Pallet table
Datum table
(.P)
(.D)
7226.0*
7226.1*
0 to 255 =
number of reserved entries
(can be expanded via soft key)
10
10
Size of NC memory for
DNC mode
Minimum
Maximum
7228.0
7228.1
08
08
1 to 1024 [kBytes]
1 to 1024 [kBytes]
1
100
Length of program
- to check the program
- up to which FK blocks are permitted
7229.0
7229.1
-
-
-
-
100 to 9999
100
Changing the dialog language
7230*
-
0 = 1. language
1 = 2. language
0
Changing the dialog language
NC dialog
PLC dialog (OEM cycles,
USER parameters)
PLC error messages
7230.0
7330.1
7230.2
-
-
-
-
-
-
0 = English
6 = Portuguese
1 = German
7 = Swedish
2 = Czech
8 = Danish
3 = French
9 = Finnish
4 = Italian
10 = Dutch
5 = Spanish
1
1
1
Deviation from Greenwich time
7235
-
-
-23 to +23 [hours]
0 =
Greenwich time
1 =
CET
2 =
Central European summer time
The factory setting of the internal clock of the control is Greenwich time. To
adapt the time of the program manager to the local time, the difference
between local time and Greenwich time must be entered in MP 7235.
* accessible via code number 123
06.03.95
5.2
52