Westermo GDW-11 User Manual
Page 55

Security commands 55
6615-2220
1: Voice (telephony)
2: Data (apply to all bearer services)
4: Fax (facsimile services)
8: Short Message service
7: Equal to all classes (Default value)
Any attempt to combine different classes will result in activation / deactivation / interro-
gation of voice, data and fax.
If
Password maximum length is given with the AT+CPWD=? Command.
NOTE
It will not be possible to lock the FDN phonebook if this one is not loaded.
Command example
Possible responses
Note
AT+CLCK=”SC”,1,1234 OK
Enable PIN, PIN was
correct
AT+CLCK?
+CLCK:(“PS”,0),(“SC”,0),
Read PIN status, PIN is
(“FD”,0),(“PN“,0),(“PU“,0),
enabled, no SIM lock, no
(“PP“,0),(“PC“,0)
network lock, no informa-
OK
tion on Call barring (no
longer supported in GSM
07.07)
AT+CLCK=”SC”,0,5555 +CME
ERROR:
16
Disable PIN, PIN was
wrong
AT+CPIN=1234
OK
Enter PIN, PIN was good
AT+CLCK=?
+CLCK:
Request supported facili-
(“PS”,”SC”,”AO”,”OI”,”OX”,
ties, Supported facilities
”AI”,”IR”,”AB”,”AC”,”FD”,
”PN”,
”PU”,”PP”,”PC”)
OK
AT+CLCK=”PN”,1,12345678 OK
Activate network lock,
Network lock activated
AT+CLCK=”AO”,1,1234,2 OK
Activate all outgoing calls
barring for data calls Call
barring is activate
AT+CLCK=”AO”,2
+CLCK : 1,2
Query BAOC status,
OK
BAOC activate for data
calls
only
AT+CLCK=”SC”,0,0000 +CME
ERROR:
521
Disable PIN, PIN deactiva-
tion is forbidden with this