6615-2220
*WIOP – Generic I/O parameters
Description:
This command set the I/O parameters.
Syntax:
AT*WIOP=
Parameters:
Min trig pulse time in 10 ms increments [1-255].
This parameter sets the minimum time the pulse must be active. A pulse shorter than
this time will be skipped.
Max trig pulse time in 10 ms increments [1-255]
Sets the maximum active with of a pulse, if pulse is longer the pulse will be skipped.
The number of pulses will be calculated when the time between pulses is longer than
3 times tmin.
Trig source and type according to the table below:
0:
NO, Trigger not used
1:
LEVEL, Trigger source is the Digital input Level
2:
PULSE, Pulsed trigger used
3:
DCD, Trigger internally coupled to reflect the DCD signal
4:
DTR, Trigger internally coupled to reflect the DTR signal
Trigger level.
0:
NO, Trigger not used
1:
HIGH, Defines that a High level triggers the service
2:
LOW, Defines that a Low level triggers the service
3:
POS, A positive edge triggers the service.
4:
NEG, A negative edge triggers the service.
The source controlling the output.
0:
NO, Output not used
1:
IO operation, Controlled by remote I/O Transparent or Out
2: Reserved
3:
DCD, Output will be controlled by DCD. An active DCD will activate the output.
4:
DTR, Output will be controlled by DTR. An active DTR will activate the output.