Wopen – open at control command – Westermo GDW-11 User Manual
Page 202

202 Specific AT commands
6615-2220
+WOPEN – Open AT control command
Description:
This command allows to start, stop, delete and get information about the current Open
AT embedded application.
Note: This command is only available if the Open AT feature is enabled (see +WCFM
command).
Syntax:
AT+WOPEN=
Response syntax:
+WOPEN:
Parameters:
0:
Stop the Open-AT embedded application. If the product was running, it resets.
1:
Start the Open-AT embedded application. If the product was stopped, it resets.
2:
Get the Open AT library versions.
3:
Erase the objects flash of the Open-AT embedded application.
4:
Erase the Open-AT embedded application.
5:
Suspend (in WESTERMO software kernel) the Open AT embedded application tasks.
NOTE:
Mode = 3 and 4 are only available if Open-AT embedded application is stopped
(AT+WOPEN=0).
Open AT embedded applications can be resumed with AT+WOPENRES command or the
INTERRUPT feature (see +WCFM command).
ASCII string giving the internal Open AT library version.
ASCII string giving the external Open AT library version.
NOTE:
If no embedded application is loaded, the