Wiot – generic i/o test – Westermo GDW-11 User Manual
Page 253

I/O commands – only in GDW-12 253
6615-2220
Command example
Possible responses
Note
AT*WIOL=4?
4_Service=TRANS
List the entry table:
4_Flag=RETRY
List entry 4
4_Timeout=040
4_Priority=YES
4_Data1=016428250
4_Data2=
4_Data3=
4_Data4=
4_Data5=
4_Data6=
*WIOT – Generic I/O test
Description:
This command executes the specified entry as if it was trigged by the normal trigger
condition.
Syntax:
AT*WIOT =
Parameters:
IO entry index number (0 – 10) 1 – 10 selects the entry at the corresponding index
in the table. Selecting entry_num =0 selects the local output, the state of the output is
selected with parameter I/O_state
The state to set the local output ( 0 or 1) when entry_num is set to 0.
Command example
Possible responses
Note
AT*WIOT =2
OK
Trigger and execute entry
2 in the table
AT*WIOT =?
*WIOT: (0-10)[,(1-1)]
OK