+CCED – Cell environment description
Description:
This command can be used by the application to retrieve the parameters of the main cell
and of up to six neighboring cells.
There are two possible methods for the external application to ascertain these cell
parameters:
… On request by the application or
… Automatically by the product every 5 seconds.
Automatic mode is not supported during registration.
Syntax:
AT+CCED=
Parameters:
0:
One shot requested
1:
Automatic shots requested
2:
Stop automatic shots
1: Main
Cell:
… If the Cell Identity is available
MCC, MNC, LAC, CI, BSIC, BCCH Freq (absolute), RxLev, RxLev Full, RxLev Sub,
RxQual, RxQual Full, RxQual Sub, Idle TS
… If the Cell Identity is not available
MCC, MNC, LAC,, BSIC, BCCH Freq (absolute), RxLev, RxLev Full, RxLev Sub,
RxQual, RxQual Full, RxQual Sub, Idle TS
2:
Neighbour1 to Neighbour6:
… If the Cell Identity is available
MCC, MNC, LAC, CI, BSIC, BCCH Freq (absolute), RxLev
… If the Cell Identity is not available
MCC, MNC, LAC,, BSIC, BCCH Freq (absolute), RxLev
4: Timing
Advance
8:
Main cell RSSI indications (RxLev), in a range from 0 to 31