Wcbtabx – secure callback table – Westermo GDW-11 User Manual
Page 258

258 Callback security commands – only in GDW-12
6615-2220
*WCBTABx – Secure callback table
Description:
This command is used to store the numbers used in the callback and the secure access
functionality.
Three different numbers can be stored.
Syntax:
AT*WCBTAB1=
AT*WCBTAB2=
AT*WCBTAB3=
Parameters:
A callback number or ‘-‘ to clear the number
NOTE:
Maximum number of entries = 3
Maximum length of number = 20 digits.
Command example
Possible responses
Note
AT*WCBTAB1=123456 OK
set entry number 1 to
number 123456.
AT*WCBTAB1=- OK
clear
entry
number
1
AT*WCBTAB2=98765432 OK
set entry number 2 to
number 98765432.
AT*WCBTAB2?
*WCBTAB2: 98765432
show entry number 2
AT*WCBTAB?
*WCBTAB1:
show all entries
*WCBTAB2:
98765432
*WCBTAB3:
See also the following commands: *wcbpwd, *wcb, capawcbtime