Wrap – remote access password – Westermo GDW-11 User Manual
Page 255

I/O commands – only in GDW-12 255
6615-2220
Command example
Possible responses
Note
AT*WIOP=50,100,1,1,3 OK
Set input min pulse width
to 500 ms max pulse width
to 1s, trigged on high level
and output to follow DCD
AT*WIOP=,,2,, OK
Change input type to be
pulse trigged
AT*WIOP?
*WIOP : TMIN=50, TMAX=
Current value
100,
TYPE=2,
TRIG=1,
NORM=3
OK
*WRAP – Remote access password
Description:
This command set the remote access password.
Syntax:
AT*WRAP =
Remote access password (6-20 characters) setting password to – will delete the previous
password.
Command example
Possible responses
Note
AT*WRAP=QwErTy OK
Set password to “QwErTy”
AT*WRAP=?
*WRAP : (6-20 char)
Test commands
OK