Wiol – generic i/o list – Westermo GDW-11 User Manual
Page 248

248 I/O commands – only in GDW-12
6615-2220
*WIOL – Generic I/O list
Description:
This command is used to program the list of I/O entries with parameters and data.
The list can contain up to 10 entries
Syntax:
Set up a service entry:
AT*WIOL=
NOTE:
List all table entries. Listing will pause ever 3.th entry and wait for any key hit to con-
tinue. ESC will terminate.
Parameters:
IO entry number, up to eight entries can be defined.
IO entry service, value as described in table below:
0:
NONE, No service defined for this entry
1:
DIAL, Makes a connection to the number defined in
2:
SMS, data fields defined as described below:
SMS-message.
3:
TEXT, Make a connection to number defined in
4:
EMAIL, Reserved for future use, service not implemented
5:
OUT, Make a connection to the number defined in
remote output according to pattern defined in string defined in
nection is terminated after the pattern is transferred.
6:
CMD, AT command specified by
7:
TRANS, Makes a connection to number defined by
transparently between the two units. The transparent mode must be ended by a
timeout.