174 Specific AT commands

6615-2220

NOTE:

… The response for the requested dump 1, 2 and 4 will be:

+CCED:, . . . ,
OK

where is the ASCII string of the values (in decimal form except the LAC
and CI values which are in hexadecimal form) of the parameters. If a field cannot be
measured – or is meaningless – the parameter is not filled in, and two consecutive
commas are sent.

… The response for the requested dump 8 will be a +CSQ response and not a

+CCED response. The 07.07 format for +CSQ is respected. The is not evalu-
ated by this command, so the value will always be 99.

+CSQ:, 99

OK

When automatic shots are selected, this +CSQ response is sent every time the
measured by the product changes. Automatic shots are supported in idle
mode and during communication. The activation or deactivation of this flow (8)
does not affect the other flows.

… In idle mode, only RxLev measurements (on the main cell and on the neighboring

cells) are made.

… Combination of the requested dump is supported (addition of the values 1, 2, 4

and 8):

1:

+CCED response: Main Cell only

2:

+CCED response: Neighbors 1 to 6

3:

+CCED response: Main Cell, then Neighbors 1 to 6

4: +CCED

response:

Timing

Advance

only

5:

+CCED response: Main Cell, then Timing Advance

6:

+CCED response: Neighbors 1 to 6, then Timing Advance

7:

+CCED response: Main Cell, then its Timing Advance, then Neighbors 1 to 6, with
each Timing Advance inserted between cells results

8:

+CSQ response: Main Cell RSSI indications

9:

+CSQ response, then +CCED response with Main Cell only

10: +CSQ response, then +CCED response with Neighbors 1 to 6

11: +CSQ response, then +CCED response with Main Cell, then Neighbors 1 to 6

12: +CSQ response, then +CCED response with Timing Advance only

13: +CSQ response, then +CCED response with Main Cell, then Timing Advance

14:

+CSQ response, then +CCED response with Neighbors 1 to 6, then Timing
Advance

15:

+CSQ response, then +CCED response with Main Cell, then its Timing Advance,
then Neighbors 1 to 6, with each Timing Advance inserted between cells results